11) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
12) Carefully push wire connections back into outlet box making
sure all connections remain secure.
13) Slip canopy over mounting screws and backpan. NOTE: Be
certain wires do not get pinched between backpan and
canopy.
14) Secure canopy to backpan using threaded caps.
15) Set glass down over socket.
16) Thread socket ring onto socket. (DO NOT over tighten.)
17) Insert recommended bulb. CAUTION: DO NOT touch bulb
with bare hands. If this happens, clean bulb with denatured
alcohol and a lint free cloth.
18) Slip glass sleeve over bulb.
LOOP/CHAIN LINK MOUNT
1) Follow steps 1, 2 and 3 from Stem Mount Instructions.
2) Screw loops onto end of each threaded pipe.
3) Add one chain link to each loop and add second loop to each
chain link.
4) Screw threaded pipe into end of each loop.
5) Pass each threaded pipe on loops through holes in canopy.
6) Slip one lockwasher over end of each threaded pipe and
screw one hexnut onto threaded pipes.
7) Follow steps 6 - 18 from Stem Mount Instructions.
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turnoffandallowtocoolbeforereplacingbulb.
• BulbgetsHOTQUICKLY!Contactswitchonlywhenturningoff.
• DONOTremaininlightifskinfeelswarm.(Lightisintense,
may cause “sunburn”)
• DONOTlookdirectlyatlightedbulb.
• Keepmaterialsawayfrombulbthatmayburn.
• UseONLYwithwattagespeciedorlower.
• DONOTtouchbulbatanytime,useasoftcloth.Oilfromskin
may damage bulb.
• DONOToperatexturewithmissingordamagedglass.
RIGID STEM MOUNT
1) Pass wire through stems and screw stems into couplings on
topofxturebody.
NOTE: Thread locking compound must be applied to all stem
threads as noted with symbol (3) to prevent accidental
rotationofxtureduringcleaning,relamping,etc.
2) Passxturewirethroughremainingstemsandscrewstems
together.
3) Screw small threaded pipe onto top of stems.
4) Pass holes in canopy over threaded pipe on top of stems.
5) Slip lockwasher over end of each threaded pipe and screw
hexnut onto end of each threaded pipe.
6) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s),thatcontrolthepowertothextureorroomthat
you are working on.
c) Placethewallswitchinthe“OFF”position.Ifthextureto
be replaced has a switch or pull chain, place those in the
“OFF” position.
7) At the center of the backpan are knockout slots. Remove the
set that matches your outlet box.
8) Secure the backpan to the outlet box.
9) Anchor the backpan to the ceiling using the set of holes at
eachendofxtureusingwoodscrews,togglebolts,plastic
anchors, etc.
10) Grounding instructions: (See Illus. A or B).
A) Onxtureswheremountingstrapisprovidedwithahole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole
in mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector, (not
provided) after following the above steps. Never
connect ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
IS-42017-USDate Issued: 12/28/12
LOOP/CHAIN LINK
LAZO/ ESLABÓN DE CADENA
BACKPAN
PLACADEMONTAJE
GLASS
VIDRIO
CANOPY
ESCUDETE
STEM
VARILLA
3
LOOP
ANILLO
CHAINLINK
ESLABÓNDE
CADENA
THREADEDPIPE
TUBO ROSCADO
STEM
VARILLA
RIGID STEM MOUNT
MONTAJE DEL VÁSTAGO NERVADO
THREADEDCAP
TAPA ROSCADA
THREADEDCAP
TAPA ROSCADA
HEXNUT
TUERCA
HEXAGONAL
BULB
BOMBILLA
GLASSSLEEVE
CAMISA DE VIDRIO
SOCKETRING
ANILLODEL
CASQUILLO
Vedere la pagina 0
1 2

Sommario

Pagina 1

11) Make wire connections (connectors not provided.) Reference chart below for correct connections and wire accordingly.12) Carefully push wire

Pagina 2

11)Hacerlasconexionesdelosalambres(conectoresnoincluidos.) Ver el cuadro más abajo para las conexiones correctas y alambrar de acu

Modelli collegati 42432 | 43059 | 42436 | 65353 |

Commenti su questo manuale

Nessun commento